Next Article in Journal
Predicting Absorption-Distribution Properties of Neuroprotective Phosphine-Borane Compounds Using In Silico Modeling and Machine Learning
Next Article in Special Issue
Activity of Experimental Mouthwashes and Gels Containing DNA-RNA and Bioactive Molecules against the Oxidative Stress of Oral Soft Tissues: The Importance of Formulations. A Bioreactor-Based Reconstituted Human Oral Epithelium Model
Previous Article in Journal
Artemisia abrotanum L. (Southern Wormwood)—History, Current Knowledge on the Chemistry, Biological Activity, Traditional Use and Possible New Pharmaceutical and Cosmetological Applications
Previous Article in Special Issue
Retaining Skin Barrier Function Properties of the Stratum Corneum with Components of the Natural Moisturizing Factor—A Randomized, Placebo-Controlled Double-Blind In Vivo Study
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Multi-Target Strategy to Uncover Unexpected Compounds in Rinse-Off and Leave-On Cosmetics

Department of Analytical Chemistry, Nutrition and Food Science, Faculty of Chemistry, CRETUS Institute, Universidade de Santiago de Compostela, E-15782 Santiago de Compostela, Spain
*
Author to whom correspondence should be addressed.
Molecules 2021, 26(9), 2504; https://doi.org/10.3390/molecules26092504 (registering DOI)
Submission received: 9 April 2021 / Revised: 22 April 2021 / Accepted: 23 April 2021 / Published: 25 April 2021
(This article belongs to the Special Issue Last Advances in Cosmetics and Personal Care Products Analysis)

Abstract

:
The wide range and complexity of cosmetic formulations currently available on the market poses a challenge from an analytical point of view. In addition, during cosmetics manufacture, impurities coming from raw materials or formed by reaction of different organic compounds present in the formulation may be present. Their identification is mandatory to assure product quality and consumer health. In this work, micro-matrix solid-phase dispersion (μMSPD) is proposed as a multi-target sample preparation strategy to analyze a wide number of unexpected families of compounds including polycyclic aromatic hydrocarbons (PAHs), pesticides, plasticizers, nitrosamines, alkylphenols (APs), and alkylphenol ethoxylates (APEOs). Analytical determination was performed by gas chromatography-mass spectrometry (GC-MS) for the determination of 51 target compounds in a single run, whereas liquid chromatography tandem mass spectrometry (LC-MS/MS) was employed for the analysis of six APs and APEOs. Both methodologies were successfully validated in terms of linearity, accuracy, and precision in leave-on and rinse-off cosmetics. Limits of detection (LODs) were calculated in the low ng g−1, showing their suitability to determine trace levels of impurities and banned compounds with different chemical natures, providing useful tools to cosmetic control laboratories and companies.

Graphical Abstract

1. Introduction

Cosmetics are complex matrices made up of large numbers and types of chemical compounds. In Europe, the Regulation EC 1223/2009 establishes rules to be complied with by any cosmetic product made available on the market, to ensure the functioning of the internal market and a high level of protection of human health [1]. In this way, the banned compounds and those restricted in terms of maximum permitted concentration are displayed in the different annexes (II and III, respectively) of the Regulation, which is in continuous review and update since its introduction [2]. In addition, to assure consumers health and to inform them about unsafe products, the European Commission has the Rapid Alert System (RAPEX), an early warning system for safety management. In the last 5 years, 419 products were withdrawn from the market due to the presence of forbidden compounds in their formulation [3].
The presence of banned substances is usually not due to the intentional addition by the manufacturer. They can proceed from impurities of allowed ingredients, or they can be formed by reaction of different organic compounds present in the formulation under particular setting conditions. A European Commission implementation decision [4] clearly states that the presence of traces of prohibited substances and impurities must remain at a level that is as low as reasonably achievable (ALARA) following Good Manufacturing Practice (GMP). When such presence is technically unavoidable, the cosmetics manufacturers are required to provide evidence of the technical unavoidability. That means they have to justify the presence of those traces by all necessary means. It is also recommended, especially in the case of non-threshold genotoxic and carcinogenic substances, that the cosmetic industry should keep improving its best practices in order to eliminate these substances in the finished cosmetic product. Among the unexpected families of compounds, polycyclic aromatic hydrocarbons (PAHs), pesticides, plasticizers, nitrosamines, alkylphenols (APs), or alkylphenol ethoxylates (APEOs), could be present in cosmetics.
Several cosmetic formulations, especially leave-on ones, are petrolatum or mineral oil-based to obtain a specific viscosity or to create a protector film on the skin (e.g., lip balms) [5]. However, permitted ingredients that come from petroleum distillation that might not be complete, may introduce PAHs in the final products through manufacturing processes. For their toxicity and carcinogenic properties, 16 PAHs have been catalogued as priority pollutants by the United States Environmental Protection Agency (EPA). The Regulation EC 1223/2009 listed PAHs as prohibited substances in cosmetic products and also set the content of benzo[a]pyrene (B[a]P) in raw material such as paraffin waxes and creosote oil to less than 0.005% w/w [1].
The presence of botanical-derived ingredients such as natural extracts or essential oils in cosmetics formulations is increasing, being considered as a positive quality by consumers [6]. However, pesticides can be used to improve the growth of the plants used as raw material and, although there is still no regulation of maximum residue levels (MRLs) for such plant-derived extracts, trace concentrations of pesticides could be detected in the finished products [7].
Plasticizers are employed in several cosmetic products such as nail polishes and hair sprays, and as solvents and perfume fixatives in many other products. These chemicals are linked to hormone disruption, which can affect development and fertility. However, whereas several of them such as dimethylphthalate (DMP) or diethylphthalate (DEP) are not restricted in their use as cosmetic ingredients, the majority of phthalates and bisphenol A (BPA) are completely forbidden. Despite this, the presence of banned plasticizers in cosmetics formulations have been reported, being mainly associated with a continuous migration from the plastic package. In fact, in products with plastic applicators to facilitate the transfer of the product to the area of application, it has been demonstrated that the level of phthalates provided by the applicator varies between 70–90% [8,9,10,11].
The presence of trace levels of nitrosamines in cosmetics is related with their presence in the raw materials, or they can be formed in their own formulation via reaction of nitrogen-containing compounds, especially secondary or tertiary amines, and nitrosating agents, such as nitrogen oxides or other allowed ingredients containing nitro groups, like the preservatives bronopol or bronidox. In this way, the Regulation establishes for allowed ingredients a maximum concentration of N-nitrosamine impurities of 50 µg kg−1, as well as its storage in nitrite-free containers [1].
APEOs are nonionic surfactants commonly used as emulsifiers and foaming agents. However, their biodegradation generates alkylphenols (APs), considered endocrine disruptors for their estrogenic effects. For this reason, APs are forbidden in the formulation of cosmetic products according to the Regulation EC 1223/2009, while some of the APEOs themselves, such as 4-nonylphenol ethoxylate (mono-, di, tri-) and their other forms marketed under the name of NP40 Alternative, continue to be used as emulsifying agents and surfactants in cosmetic products, although they must be controlled for their potential conversion into prohibited APs.
Taking into account the wide number of banned or unexpected compounds that could be present in the final cosmetic products, the cosmetic sector demands the development of reliable, fast, and easy-to-implement methodology to be able to determine a high number of compounds in a broad range of products in a single run.
The major drawback for the analysis of cosmetics is sample preparation since these matrices are complex and diverse. Most of the reported methodologies for their analysis are focused on specific families, that usually include a few target compounds or compounds with similar chemical properties [2,12,13]. Regarding sample preparation, solid–liquid (SLE) or liquid–liquid extraction (LLE) have been the most applied. However, they require high amounts of organic solvents and laborious experimental steps. Direct dilution (or ready-to-inject) is also one of the most employed procedures, but its main drawback is that it is a suitable option just for perfumes or simple matrices [14], but it is not adequate for complex matrices such as most of the currently marketed products, where a high number of compounds at different concentrations coexist. Besides, from a practical point of view, this approach can negatively affect the chromatographic system.
Therefore, the development of environmentally friendly sample preparation procedures that also imply an in situ clean-up step is a good and needed approach. In this way, matrix solid-phase dispersion (MSPD) has been proposed for the extraction of different families of cosmetic ingredients [15,16,17]. However, new trends in cosmetics sample preparation are moving towards the development of miniaturized procedures that comply with the green chemistry principles, and techniques such as solid-phase microextraction (SPME), ultrasound-assisted emulsification microextraction (USAEME), or stir bar sorptive dispersive microextraction (SBSDME) have been applied for the determination of fragrances, antioxidants, preservatives, PAHs, or MVOCs in cosmetics and personal care products [18,19,20,21,22,23]. In this way, a miniaturization of the classical MSPD (μMSPD), employing disposable low-cost material and a low organic solvent consumption (1 mL) is proposed as a suitable sample preparation technique. μMSPD has been reported for the extraction of allowed cosmetic ingredients such as fragrances, dyes, or UV filters [24,25,26,27]. However, to the best of our knowledge, this miniaturized technique has never been applied for the determination of a broad range of banned or unexpected compounds in cosmetics and personal care products.
Thus, the main goal of this work is the development of a multi-target strategy based on miniaturized sample preparation techniques followed by chromatographic analysis to cover a broad range of banned compounds with different chemical natures in leave-on and rinse-off cosmetics, providing useful tools to cosmetic control laboratories and production companies.

2. Results and Discussion

The target compounds, their CAS numbers, retention times, and quantification and identification ions (or MS/MS transitions for APEOs) are summarized in Table 1. A total number of 57 compounds including PAHs, pesticides, plasticizers, nitrosamines, APs, APEOs, oxidative dyes, and fragrances were considered. All of them, excluding APEOs that present different restriction levels (see footnotes in Table 1), are currently included in the Annex II “List of substances forbidden in cosmetics” of the Regulation EC No 1223/2009 [1].

2.1. Chromatographic Analysis

Since cosmetic formulations contain complex mixtures of several classes of different ingredients, the required multicomponent analysis becomes a challenge, making resolutive chromatography necessary [2,23]. Traditionally, cosmetics analysis methodology was based on liquid chromatography (LC) or gas chromatography (GC), offering both techniques robustness and a high-resolution power.
Choosing between GC or LC is mainly based on the physicochemical properties of the target analytes. In this work, since all the compounds (excluding APs and APEOs) were volatile or semivolatile, GC was proposed as the separation technique. For APs and APEOs, more polar and less volatile compounds, LC was selected as the most suitable option. It is important to note that few works regarding the determination of APs and APEOs in cosmetics and personal care products are reported in the literature since nonionic surfactants analysis represents a much higher level of complexity than other types of surfactants because several hundreds of individual substances may occur in a mixture [28]. This fact, together with the usual complexity of cosmetic matrices, make their analysis a challenge.
Chromatography with UV-based detectors has been the most employed technique for the determination of compounds present at high concentrations in the final products, such as preservatives, UV filters, or dyes [12]. However, to determine trace levels of banned compounds or impurities, the use of more selective detectors such as those based on mass spectrometry (MS) offer the selectivity and sensitivity required [29]. Therefore, in this work, GC-MS, working in the selected ion monitoring (SIM) mode, was selected for the analysis of PAHs, pesticides, plasticizers, nitrosamines, and the other target compounds (dyes, fragrances), making a total of 51 compounds.
On the other hand, to determine APEOs, fluorescence detection (FLD) has been the most selected and simple option. However, since the presence of APs is forbidden in cosmetics, LC coupled to tandem mass spectrometry (LC-MS/MS) working in the selection reaction monitoring (SRM) mode was selected as the determination technique for both the parent surfactants and their biodegradation products.
In all cases, the chromatographic and determination conditions were optimized to obtain the highest separation and resolution efficiencies for an unequivocal identification of the target compounds. Conditions are summarized in Section 3.4. Figure 1 shows a SRM extracted (quantification transition) LC-MS/MS chromatogram for the considered APs and APEOs.

2.2. Sample Preparation Strategies

The latest advances in efficient and easy-to-implement cosmetic sample preparation methodology, as previously mentioned, have been focused on the development of miniaturized devices and procedures, reducing organic solvent consumption and sample amount, improving performance and, thus, lessening the environmental impact.
In this way, μMSPD was selected as the extraction technique. Figure 2 shows the experimental procedure, which is further explained in Section 3.3.

2.3. Methods Performance

The proposed methodologies have been validated in terms of linearity, accuracy, and precision to show their suitability for the application to both leave-on and rinse-off cosmetics. In addition, limits of detection (LODs) were calculated. The methods performance parameters are summarized in Table 2 and Table 3 for µMSPD-GC-MS and µMSPD-LC-MS/MS, respectively.

2.3.1. µMSPD-GC-MS

Calibration standards were prepared in ethyl acetate covering a concentration range between 10 and 2000 µg L−1 (plasticizers: 50–2000 µg L−1). The method exhibited a direct proportional relationship between the amount of each analyte and its chromatographic response, with coefficients of determination (R2) higher than 0.9910 in all cases (see Table 2).
Instrumental method precision was evaluated within a day (n = 3), and among days (n = 6) for all the calibration concentration levels. Relative standard deviation (RSD) values for 100 µg L−1 are also shown in Table 2. In all cases, the RSD values were lower than 9% and 11% for repeatability and reproducibility, respectively. To assess the accuracy of the proposed methodology, recovery studies were carried out employing two cosmetics samples: leave-on (moisturizing hand cream) and a rinse-off (shower gel) products. The study was performed by a sample addition of 100 µg g−1 for all compounds, for a validation range of 1 to 10 µg g−1, the actual concentrations in the injected dilutions, according to the potential presence of impurities in the finished cosmetic product under the ALARA principle. The spiked samples were extracted by µMSPD by triplicate and analyzed by GC-MS. As can be seen in Table 2, good accuracy and precision were achieved, with recovery values between 72–116%, and RSD values lower than 15% in all cases. Limits of detection (LODs) were calculated as the compound concentration giving a signal-to-noise ratio of three (S/N = 3) employing samples spiked with the target compounds. For the compounds that were detected in the whole procedure blanks (DIBP, DBP, and DEHP), LODs were calculated as the average amount of analyte giving a response that is the blank signal plus three times the standard deviation. Results are depicted in Table 2, and they were at the low ng g−1 level for all target compounds. Compared with other analytical methodologies based on GC-MS, the proposed µMSPD-GC-MS approach presents lower LODs (up to two orders of magnitude) than those reported for the analysis of PAHs or nitrosamines in cosmetics employing solid–liquid extraction-GC-MS/MS [30,31]. Other advantages of the proposed µMSPD procedure are that only 1 mL of organic solvent (ethyl acetate) is required, and the inclusion of an in situ clean-up step allows for a high fractionation degree, obtaining clean extracts that can be directly injected without further preparation steps.

2.3.2. µMSPD-LC-MS/MS

Calibration standards were prepared in acetonitrile/water (50:50, v/v) covering a range between 2 and 10,000 µg L−1. The specific linear range for each target compound is shown in Table 3. The method exhibited a direct proportional relationship between the amount of each analyte and its chromatographic response, with coefficients of determination (R2) higher than 0.9974 in all cases.
Instrumental method precision was evaluated within a day (n = 3) and among days (n = 6) for all the calibration concentration levels. Relative standard deviation (RSD) values for 100 µg L−1 are also shown in Table 3. In all cases, the RSD values were lower than 10% for repeatability and reproducibility.
It is well-known that matrix effect, the ionization suppression or enhancement of the analyte of interest by other compounds present in the sample, becomes a major problem for the analysis of complex samples, such as cosmetics, using LC-MS/MS. Matrix effect was assessed for each of the target APs and APEOs by comparing the slopes obtained for external calibration and those obtained employing matrix-matched calibration. Results are shown in Table S2. For the rinse-off sample (shower gel), values resulting from dividing the slope of both curves were 1.0 ± 0.2, demonstrating that no matrix effects exist. However, for OPEO and Triton X-100, positive and negative matrix effects were observed, respectively, for the leave-on (moisturizing cream) cosmetic. Therefore, for these two compounds, matrix-matched calibration is recommended to analyze leave-on samples, whereas for the rinse-off ones, external calibration employing standards prepared in acetonitrile/water (50:50, v/v) is a suitable option. Recovery studies were carried out employing both samples spiked at 20 µg g−1 for all APs and APEOs. The spiked samples were extracted by µMSPD by triplicate and analyzed by LC-MS/MS. As can be seen in Table 3, recovery values ranged between 83 and 106%, with RSD values lower than 11% in all cases. LODs were also calculated as the compound concentration giving a signal-to-noise ratio of three (S/N = 3) since none of the target compounds were detected in the procedure blanks. Obtained values ranged between 0.09 and 1.30 ng g−1 being well below, by up to 2 orders of magnitude, those reported in the literature employing ultrasound assisted extraction (UAE)-LC-FLD or solid–liquid extraction followed by LC-MS/MS [32,33].

3. Materials and Methods

3.1. Reagents and Materials

The 57 target compounds, their CAS numbers, retention times, and MS ions or MS/MS transitions are summarized in Table 1. Ethyl acetate was supplied by Sigma-Aldrich Chemie GmbH (Steinheim, Germany), acetonitrile (MS grade) and acetone were provided by Fluka Analytical (Steinheim, Germany). Water (MS grade) was purchased from Scharlab (Barcelona, Spain). Anhydrous sodium sulfate, Na2SO4 (99%) was obtained from Panreac (Barcelona, Spain). Florisil® (60–100 µm mesh) and glass wool were purchased form Supelco Analytical (Bellefonte, PA, USA). Individual stock solutions of each target analyte were prepared in ethyl acetate or methanol for APs and APEOs. Further dilutions and mixtures were prepared in ethyl acetate or acetonitrile/water (50:50, v/v) for GC-MS and LC-MS/MS analysis, respectively, and in acetone for spike solutions. All solutions were stored at −20 °C. All reagents were of analytical grade.
Since the target compounds include plasticizers (mainly phthalates that are ubiquitous compounds), to avoid contamination during the experimental procedure, all the plastic material was substituted, as far as possible, by glass or metallic material that was kept at 230 °C for at least 12 h before its use.

3.2. Cosmetic Samples

Two cosmetic samples, a moisturizing hand cream (leave-on) and a shower gel (rinse-off) were selected to validate the proposed methodology. Both samples were selected because they were labeled as fragrance, parabens, and silicone free (leave-on sample composition: aqua (water), paraffinum liquidum, glycerin, glyceryl stearate se, bis-diglyceryl polyacryladipate-2, stearic acid, cetearyl alcohol, urea, potassium stearate, creatine, 1,2-hexanediol, caprylyl glycol, tropolone; rinse-off sample composition: Aqua, sodium laureth sulfate, glycerin, cocamidopropyl betaine, sodium chloride, coco-glucoside, parfum, sodium lactate, lactic acid, sodium benzoate). They were kept in their original containers and protected from light at room temperature until their use.

3.3. Micro-MSPD Procedure

The µMSPD procedure was adapted from that previously developed by the authors for the extraction of fragrances, UV filters, or preservatives from cosmetic and personal care products [9,26,27]. Briefly, 0.1 g of cosmetic samples were weighted into a 10 mL glass vial. Then, the sample was gently blended with 0.2 g of Na2SO4 (drying agent) and 0.4 g of Florisil® (dispersant) in the vial, using a glass rod, until a homogeneous mixture was obtained. The mixture was then transferred into a glass Pasteur pipette (150 mm), containing a small amount of glass wool at the bottom, and about 0.1 g of Florisil® (to obtain a high fractionation degree and an in situ clean-up step). Finally, a small amount of glass wool was placed on the top to compress the mixture. Elution with ethyl acetate (GC-MS analysis) or acetonitrile (LC-MS/MS analysis) was carried out by gravity flow, collecting 1 mL of extract in a volumetric flask. The obtained extracts were diluted 1:10 (v/v) in ethyl acetate (GC-MS analysis) and 1:5 (v/v) in acetonitrile/water (50:50, v/v) (LC-MS/MS analysis), filtered through 0.22 µm polytetrafluoroethylene (PTFE) filters, and analyzed by GC-MS or LC-MS/MS.
For the recovery studies, the sample was spiked with 10 µL of the corresponding acetonic solution containing the target compounds to achieve the desired final concentration of them and submitted to the same process described above. Blanks procedures were daily performed to evaluate the presence of the target compounds (mainly plasticizers) during the experimental process. Figure 2 illustrates the described µMSPD methodology.

3.4. GC-MS Analysis

The GC-MS analysis was performed using an Agilent 7890A coupled to an Agilent 5975C inert mass spectrometer detector (MSD) with triple-axis detector and an Agilent 7693 autosampler from Agilent Technologies (Palo Alto, CA, USA). The separation was achieved employing a ZB-Semivolatiles (30m × 0.25 mm i.d., 0.25 µm film thickness) column obtained from Phenomenex (Torrance, CA, USA), with a chromatographic ramp that applies 50 °C (held 3 min) to 200 °C at 4 °C min−1, and a final ramp to 290 °C at 20 °C min−1 (held 3 min). The total run time was 50 min. Helium (purity 99.999%) was employed as a carrier gas at a constant flow of 1.0 mL min−1. The sample volume was 1 µL, and the injector temperature was set at 270 °C. The MSD was operated in the electron impact (EI) ionization positive mode (+70 eV). The temperature of the ion source was 150 °C and the transfer line temperature was set at 290 °C. Selected ion monitoring (SIM) acquisition mode was employed, monitoring 2 or 3 mass/charge (m/z) fragments for each compound for an unequivocal identification.

3.5. LC-MS/MS Analysis

The LC-MS/MS analyses were performed employing a Thermo Fisher Scientific (San José, CA, USA) instrument based on a TSQ Quantum UltraTM triple quadrupole mass spectrometer equipped with a HESI-II (heated electrospray ionization), and an Accela Open autosampler with a 20 µL loop. The chromatographic separation was achieved on a Kinetex C18 EVO column (100 × 2.1 mm, 2.6 µm, 100 Å), obtained from Phenomenex. The temperature of the column was set at 30 °C. The mobile phase consisted of water (A) and ACN (B), both with 5 mM of NH4OH, since basic pH containing NH4+ ions favors the formation of [APEO+NH4]+ adducts, that present a high fragmentation grade in MS/MS.
The elution gradient started with 55% of B, it was increased to 100% of B in 7 min and kept constant for 1 min. Finally, initial conditions were reached in 3 min. The injection volume was 10 µL and the mobile phase flow-rate was 0.2 mL min−1. The total run for each injection was 25 min. The spray voltage was 3000 V, the vaporization and capillary temperatures were set at 300 and 350 °C, respectively. Pressure sheath, sweep, and auxiliary gas were kept at 28, 2, and 5 au (arbitrary units), respectively. The mass spectrometer and the HESI source were working simultaneously in the positive and negative mode, monitoring different MS/MS transitions for each compound for an unequivocal identification. Quantification MS/MS transitions are shown in Table 1 and confirmation ones are summarized in Table S1.

4. Conclusions

µMSPD has been demonstrated to be a suitable sample preparation procedure to analyze traces of prohibited substances described by the EU Cosmetics Regulation as stemming from impurities of natural or synthetic ingredients, the manufacturing process, storage, or migration from packaging, that are technically unavoidable in good manufacturing practice and, thus, whose presence is non-intended. The proposed method enables the extraction of a wide number of impurities and banned compounds such as PAHs, pesticides, plasticizers, nitrosamines, Aps, and APEOs in leave-on and rinse-off cosmetics. The use of GC-MS and LC-MS/MS as determination techniques provide the required selectivity and analyte sensitivity to detect trace levels of the target compounds. The proposed methodologies were successfully validated in terms of linearity and precision. Recovery studies were also performed, being quantitative in both cosmetic matrices. LODs were at the low ng g−1 level for all compounds. Therefore, the combination of µMSPD with chromatographic-mass spectrometric techniques appears to be a very suitable tool for cosmetic control laboratories and manufacturers to determine trace levels of the target compounds in the final products in order to assure cosmetics quality, legal compliance, and, above all, consumer and user health and safety.

Supplementary Materials

Supplementary materials are available online. Table S1. Confirmation MS/MS transitions for the APs and APEOs determination by µMSPD-LC-MS/MS, Table S2. Matrix effects assessment for APs and APEOs analysis by µMSPD-LC-MS/MS.

Author Contributions

Conceptualization, M.L. and C.G.-J.; methodology, M.C. and L.R.; validation, M.C.; formal analysis, M.C. and M.L.; investigation, M.C., L.R., C.G.-J., and M.L.; resources, M.L.; data curation, M.C.; writing—original draft preparation, M.C.; writing—review and editing, M.C., L.R., C.G.-J., and M.L.; supervision, M.L.; project administration, M.L.; funding acquisition, M.L. and C.G.-J. All authors have read and agreed to the published version of the manuscript.

Funding

This project was supported by project ED431 2020/06 (Xunta de Galicia). Authors belong to CRETUS Strategic Partnership (ED431E 2018/01) (Xunta de Galicia). All these programs are co-funded by FEDER (UE). L.R. acknowledges Xunta de Galicia for her predoctoral contract (ED481A-2018/227). This article is also based upon work from the Sample Preparation Task Force and Network supported by the Division of Analytical Chemistry of the European Chemical Society.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. The European Parliament and the Council of The European Union. Regulation (EC) No 1223/2009 of the European Parliament and of the Council of 30 November 2009 on Cosmetic Products (Recast). Available online: https://ec.europa.eu/health/sites/health/files/endocrine_disruptors/docs/cosmetic_1223_2009_regulation_en.pdf (accessed on 2 March 2021).
  2. Lores, M.; Llompart, M.; Alvarez-Rivera, G.; Guerra, E.; Vila, M.; Celeiro, M.; Lamas, J.P.; Garcia-Jares, C. Positive lists of cosmetic ingredients: Analytical methodology for regulatory and safety controls—A review. Anal. Chim. Acta 2016, 915, 1–26. [Google Scholar] [CrossRef]
  3. European Commission. Safety Gate: The Rapid Alert System for Dangerous Non-Food Products. Available online: https://ec.europa.eu/consumers/consumers_safety/safety_products/rapex/alerts/repository/content/pages/rapex/index_en.htm (accessed on 2 March 2021).
  4. The European Parliament and the Council of the European Union. Commission Implementing Decision of 25 November 2013 on Guidelines on Annex I to Regulation (EC) No 1223/2009 of the European Parliament and of the Council on Cosmetic Products (Text with EEA relevance). Available online: https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX%3A32013D0674 (accessed on 2 March 2021).
  5. Petry, T.; Bury, D.; Fautz, R.; Hauser, M.; Huber, B.; Markowetz, A.; Mishra, S.; Rettinger, K.; Schuh, W.; Teichert, T. Review of data on the dermal penetration of mineral oils and waxes used in cosmetic applications. Toxicol. Lett. 2017, 280, 70–78. [Google Scholar] [CrossRef]
  6. Sharmeen, J.; Mahomoodally, F.; Zengin, G.; Maggi, F. Essential Oils as Natural Sources of Fragrance Compounds for Cosmetics and Cosmeceuticals. Molecules 2021, 26, 666. [Google Scholar] [CrossRef]
  7. Tascone, O.; Roy, C.; Filippi, J.-J.; Meierhenrich, U.J. Use, analysis, and regulation of pesticides in natural extracts, essential oils, concretes, and absolutes. Anal. Bioanal. Chem. 2013, 406, 971–980. [Google Scholar] [CrossRef] [PubMed]
  8. Amberg-Müller, J.P.; Hauri, U.; Schlegel, U.; Hohl, C.; Brüschweiler, B.J. Migration of phthalates from soft PVC packaging into shower and bath gels and assessment of consumer risk. J. Consum. Prot. Food Saf. 2010, 5, 429–442. [Google Scholar] [CrossRef]
  9. Llompart, M.; Celeiro, M.; Lamas, J.P.; Sanchez-Prado, L.; Lores, M.; Garcia-Jares, C. Analysis of plasticizers and synthetic musks in cosmetic and personal care products by matrix solid-phase dispersion gas chromatography–mass spectrometry. J. Chromatogr. A 2013, 1293, 10–19. [Google Scholar] [CrossRef] [PubMed]
  10. Murat, P.; Puttaswamy, S.H.; Ferret, P.-J.; Coslédan, S.; Simon, V. Identification of Potential Extractables and Leachables in Cosmetic Plastic Packaging by Microchambers-Thermal Extraction and Pyrolysis-Gas Chromatography-Mass Spectrometry. Molecules 2020, 25, 2115. [Google Scholar] [CrossRef]
  11. Lores, M.; Celeiro, M.; Rubio, L.; Llompart, M.; Garcia-Jares, C. Extreme cosmetics and borderline products: An analytical-based survey of European regulation compliance. Anal. Bioanal. Chem. 2018, 410, 7085–7102. [Google Scholar] [CrossRef]
  12. Salvador, A.; Chisvert, A. Analysis of Cosmetic Products, 2nd ed.; Elsevier: Amsterdam, The Netherlands, 2017. [Google Scholar]
  13. Cabaleiro, N.; de la Calle, I.; Bendicho, C.; Lavilla, I. An overview of sample preparation for the determination of parabens in cosmetics. TrAC Trends Anal. Chem. 2014, 57, 34–46. [Google Scholar] [CrossRef]
  14. Sanchez-Prado, L.; Llompart, M.; Lamas, J.P.; Garcia-Jares, C.; Lores, M. Multicomponent analytical methodology to control phthalates, synthetic musks, fragrance allergens and preservatives in perfumes. Talanta 2011, 85, 370–379. [Google Scholar] [CrossRef]
  15. Sanchez-Prado, L.; Alvarez-Rivera, G.; Lamas, J.P.; Lores, M.; Garcia-Jares, C.; Llompart, M. Analysis of multi-class preservatives in leave-on and rinse-off cosmetics by matrix solid-phase dispersion. Anal. Bioanal. Chem. 2011, 401, 3293–3304. [Google Scholar] [CrossRef] [PubMed]
  16. Liu, Y.-F.; Zhang, J.-L.; Nie, X.-F.; Zhang, P.; Yan, X.-Q.; Fu, K.-F. Simultaneous determination of 11 preservatives in cosmetics and pharmaceuticals by matrix solid-phase dispersion coupled with gas chromatography. Acta Chromatogr. 2020, 32, 203–209. [Google Scholar] [CrossRef]
  17. Abedi, G.; Talebpour, Z.; Jamechenarboo, F. The survey of analytical methods for sample preparation and analysis of fragrances in cosmetics and personal care products. TrAC Trends Anal. Chem. 2018, 102, 41–59. [Google Scholar] [CrossRef]
  18. Pérez-Outeiral, J.; Millán, E.; Garcia-Arrona, R. Ultrasound-assisted emulsification microextraction coupled with high-performance liquid chromatography for the simultaneous determination of fragrance allergens in cosmetics and water. J. Sep. Sci. 2015, 38, 1561–1569. [Google Scholar] [CrossRef]
  19. Cabaleiro, N.; de la Calle, I.; Bendicho, C.; Lavilla, I. Current trends in liquid-liquid and solid-liquid extraction for cosmetic analysis: A review. Anal. Methods 2013, 5, 323–340. [Google Scholar] [CrossRef]
  20. Tsai, T.-F.; Lee, M.-R. Determination of Antioxidants and Preservatives in Cosmetics by SPME Combined with GC–MS. Chromatographia 2008, 67, 425–431. [Google Scholar] [CrossRef]
  21. Vállez-Gomis, V.; Grau, J.; Benedé, J.L.; Chisvert, A.; Salvador, A. Reduced graphene oxide-based magnetic composite for trace determination of polycyclic aromatic hydrocarbons in cosmetics by stir bar sorptive dispersive microextraction. J. Chromatogr. A 2020, 1624, 461229. [Google Scholar] [CrossRef] [PubMed]
  22. Celeiro, M.; Varela, E.; Rodriguez, R.; Penedo, M.; Lores, M. Tracking Bacterial Spoilage in Cosmetics by a New Bioanalytical Approach: API-SPME-GC-MS to Monitor MVOCs. Cosmetics 2020, 7, 38. [Google Scholar] [CrossRef]
  23. Zhong, Z.; Li, G. Current trends in sample preparation for cosmetic analysis. J. Sep. Sci. 2016, 40, 152–169. [Google Scholar] [CrossRef] [Green Version]
  24. Celeiro, M.; Lamas, J.P.; Llompart, M.; Garcia-Jares, C. In-Vial Micro-Matrix-Solid Phase Dispersion for the Analysis of Fragrance Allergens, Preservatives, Plasticizers, and Musks in Cosmetics. Cosmetics 2014, 1, 171–201. [Google Scholar] [CrossRef] [Green Version]
  25. Guerra, E.; Celeiro, M.; Lamas, J.P.; Llompart, M.; Garcia-Jares, C. Determination of dyes in cosmetic products by micro-matrix solid phase dispersion and liquid chromatography coupled to tandem mass spectrometry. J. Chromatogr. A 2015, 1415, 27–37. [Google Scholar] [CrossRef]
  26. Celeiro, M.; Vazquez, L.; Lamas, J.P.; Vila, M.; Garcia-Jares, C.; Llompart, M. Miniaturized Matrix Solid-Phase Dispersion for the Analysis of Ultraviolet Filters and Other Cosmetic Ingredients in Personal Care Products. Separations 2019, 6, 30. [Google Scholar] [CrossRef] [Green Version]
  27. Celeiro, M.; Guerra, E.; Lamas, J.P.; Lores, M.; Garcia-Jares, C.; Llompart, M. Development of a multianalyte method based on micro-matrix-solid-phase dispersion for the analysis of fragrance allergens and preservatives in personal care products. J. Chromatogr. A 2014, 1344, 1–14. [Google Scholar] [CrossRef]
  28. Beneito-Cambra, M.; Herrero-Martinez, J.M.; Ramis-Ramos, G. Analytical methods for the characterization and determination of nonionic surfactants in cosmetics and environmental matrices. Anal. Methods 2013, 5, 341–354. [Google Scholar] [CrossRef]
  29. van Asten, A. The importance of GC and GC-MS in perfume analysis. TrAC-Trend Anal. Chem. 2002, 21, 698–708. [Google Scholar] [CrossRef]
  30. Wang, S.-W.; Hsu, K.-H.; Huang, S.-C.; Tseng, S.-H.; Wang, D.-Y.; Cheng, H.-F. Determination of polycyclic aromatic hydrocarbons (PAHs) in cosmetic products by gas chromatography-tandem mass spectrometry. J. Food Drug Anal. 2019, 27, 815–824. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  31. Qiang, M.A.; Hai-Wei, X.I.; Chao, W.; Hua, B.A.I.; Guang-Cheng, X.I.; Ning, S.U.; Li-Yan, X.U.; Jun-Bing, W. Determination of ten volatile nitrosamines in cosmetics by gas chromatography tandem mass spectrometry. Chin. J. Anal. Chem. 2011, 39, 1201–1207. [Google Scholar]
  32. **, S.F.; Li, H.I.; Tan, J.; Wang, J.; **ong, X.; Zhao, T.; Guo, C.; **e, Q. Determination of alkyphenol ethoxylates in detergent products and cosmetics with quantitative model based on fluorescence molar absorption coefficient. J. Instrument. Anal. 2013, 7, 1. [Google Scholar]
  33. Liao, C.; Kannan, K. A Survey of Alkylphenols, Bisphenols, and Triclosan in Personal Care Products from China and the United States. Arch. Environ. Contam. Toxicol. 2014, 67, 50–59. [Google Scholar] [CrossRef]
Figure 1. SRM reconstructed LC-MS/MS chromatogram for APs and APEOs (100 µg L−1 prepared in acetonitrile/water, 50:50, v/v).
Figure 1. SRM reconstructed LC-MS/MS chromatogram for APs and APEOs (100 µg L−1 prepared in acetonitrile/water, 50:50, v/v).
Molecules 26 02504 g001
Figure 2. Schematic representation of the µMSPD experimental procedure.
Figure 2. Schematic representation of the µMSPD experimental procedure.
Molecules 26 02504 g002
Table 1. Studied compounds. CAS; retention time; and quantification and identification ions or MS/MS transitions.
Table 1. Studied compounds. CAS; retention time; and quantification and identification ions or MS/MS transitions.
CompoundsAcronymCASRet. Time
(min)
Quantification and Identification Ions (Relative Abundance)
PAHs
NaphthaleneNAP91-20-316.11128 (100), 129 (11), 127 (11)
AcenaphthyleneACY208-96-824.96152 (100), 153 (15), 151 (14)
AcenaphtheneACE83-32-926.00153 (100), 154 (83), 152 (51)
FluoreneFLU83-73-729.00166 (100), 165 (84), 167 (14)
PhenanthrenePHEN85-01-834.41178 (100), 176 (20), 179 (15)
AnthraceneANC120-12-734.70178 (100), 179 (16), 176 (14)
FluorantheneFLA206-44-041.26202 (100), 203 (17), 200 (15)
PyrenePYR129-00-042.63202 (100), 203 (17), 100 (15)
Benzo[a]anthraceneB[a]A56-55-346.49228 (100), 226 (28), 229 (20)
ChryseneCHY218-01-946.55228 (100), 226 (27), 229 (20)
Benzo[b]fluorantheneB[b]F205-99-048.41252 (100), 253 (22), 250 (18)
Benzo[k]fluorantheneB[k]F207-08-948.47252 (100), 253 (21), 250 (21)
Benzo[a]pyreneB[a]P50-32-849.06252 (100), 253 (21), 250 (27)
Pesticides
MonocrotophosMNC6923-22-432.23127 (100), 97 (21), 192 (15)
Chlorpyrifos-methylCPM5598-13-036.84286 (100), 125 (95), 288 (78)
SimazineSIM122-34-933.48201 (100), 186 (62), 173 (47)
PropazinePRZ139-40-233.92214 (100), 229 (53), 172 (47)
ChlorprophamCP101-21-331.27127 (100), 213 (30), 171 (21)
Kresoxim-methylKRM143390-89-044.31116 (100), 131 (56), 206 (52)
IprodioneIPR36734-19-746.38314 (100), 187 (70), 70 (50)
MyclobutanilMYC88671-89-044.10179 (100), 152 (40), 181 (32)
TebuconazoleTBC107534-96-345.95125 (100), 250 (50), 83 (49)
4,4′DDTDDT50-29-345.70235 (100), 237 (65), 165 (43)
CarbarylCAR63-25-237.48144 (100), 115 (56), 116 (38)
AlachlorALA15972-60-837.26160 (100), 188 (90), 237 (50)
DieldrinDIE60-57-143.8879 (100), 263 (20), 277 (15)
Plasticizers
DiisobutylphthalateDIBP84-69-536.55149 (100, 57 (15), 223 (6)
DibutylphthalateDBP84-74-238.90149 (100), 150 (9), 223 (5)
DimethoxyethylphthalateDMEP117-82-839.7659 (100), 104 (18), 149 (29)
DiisopentylphthalateDIPP605-50-541.50149 (100), 71 (28), 237 (10)
DipentylphthalateDPP131-18-046.88149 (100), 71 (16), 237 (6)
BenzylbutylphthalateBBP85-68-746.67149 (100), 91 (53), 206 (24)
Di-(2-ethylhexyl)phthalateDEHP117-81-746.88149 (100), 167 (30), 279 (10)
Bisphenol ABPA80-05-743.91213 (100), 119 (19), 228 (25)
Nitrosamines
N-nitrosodiethylamineNDEA55-18-55.96102 (100), 44 (76), 56 (54)
N-nitrosopyrrolidineNPYR930-55-211.81100 (100), 41 (69), 68 (13)
N-nitrosodipropylamineNDPA621-64-712.03130 (100), 43 (117), 70 (66)
N-nitrosomorpholineNMOR59-89-212.04116 (100), 56 (120), 86 (42)
N-nitrosopiperidineNPIP100-75-413.36114 (100), 42 (117), 55 (61)
N-nitrosodibutylamineNDBA924-16-318.9784 (100), 116 (31), 158 (15)
N-nitrosodiphenylamineNDPhA86-30-630.16168 (100), 77 (16), 167 (57)
N-nitroso-N-methylanilineNMA614-00-611.87106 (100), 77 (50), 107 (44)
N-nitroso-N-ethylanilineNEA612-64-614.2777 (100), 120 (71), 106 (46)
N-nitrosodibenzylamineNDBzA5336-53-838.0291 (100), 226 (11), 65 (14)
Other compounds: oxidative dyes and fragrances
1,4-dihydroxybenzeneHydroquinone123-39-16.86110 (100), 55 (18), 81 (31)
2-naphthol2-NAP135-19-327.24144 (100), 115 (71), 116 (24)
VersalideATTN88-29-934.81243 (100), 244 (18), 258 (27)
Musk ambretteMA83-66-935.48253 (100), 254 (13), 268 (35)
Musk moskeneMM116-66-536.80263 (100), 264 (20), 278 (9)
Musk tibeteneMT145-39-137.89251 (100), 43 (33), 266 (28)
4-(4-Hydroxy-4-methylpentyl)-3-cyclohexene-1-carboxaldehydeLyral®31906-75-431.43136 (100), 79 (74), 93 (78)
APs and APEOsAcronymCASRet. Time(min)MS/MS Transitions (Collision Energy, eV) a
NonylphenolNP25154-52-36.61219.12 → 133.0 (−44)
4-nonylphenol isomers4NP84852-15-36.61219.1 → 116.9 (−80)
4-nonylphenol ethoxylate bNPEO68412-54-46.99370.40 → 227.40 (15)
4-octylphenol ethoxylate cOPEO26636-32-86.08312.30 → 183.00 (11)
NP40 Alternative bNP409016-45-97.01414.10 → 397.40 (15)
Triton X-100 cTX-1009002-93-16.30400.30 → 383.30 (16)
a Quantification MS/MS transition. Confirmation MS/MS transitions are included in Table S1. b Used as surfactant (cleansing and emulsifying). c Not regulated according to Regulation EC No 1223/2009.
Table 2. µMSPD-GC-MS performance. Coefficient of determination (R2), precision, accuracy, and limits of detection (LOD).
Table 2. µMSPD-GC-MS performance. Coefficient of determination (R2), precision, accuracy, and limits of detection (LOD).
CompoundsR2PrecisionRecovery, %LOD
(ng g−1) a
Intra-Day,
RSD, %
Inter-Day,
RSD, %
Leave-OnRinse-Off
PAHs
NAP0.99931.210109 ± 1108 ± 101.0
ACY0.99804.39.3107 ± 597 ± 112.0
ACE0.99955.98.8116 ± 698 ± 94.0
FLU0.99912.37.5117 ± 199 ± 106.2
PHEN0.99876.34.9114 ± 297 ± 93.8
ANC0.99987.210119 ± 196 ± 113.9
FLA9.99897.411102 ± 198 ± 83.5
PYR0.99863.46.499 ± 1398 ± 102.5
B[a]A0.99883.58.7101 ± 9102 ± 111.9
CHY0.99906.01198 ± 1395 ± 92.0
B[b]F0.99743.21394 ± 7106 ± 1410
B[k]F0.99723.56.794 ± 898 ± 1610
B[a]P0.99841.84.389 ± 9101 ± 912
Pesticides
MNC0.99781.23.2n.c.99 ± 3250
CPM0.99723.24.5106 ± 8105 ± 105.9
SIM0.99104.16.3108 ± 7107 ± 1150
PRZ0.99712.15.8100 ± 398 ± 270
CP0.99325.41089 ± 3100 ± 190
KRM0.99781.04.2104 ± 10112 ± 115
IPR0.99943.61087 ± 7120 ± 450
MYC0.99681.32.6102 ± 6120 ± 17.5
TBC0.99921.25.6113 ± 16100 ± 29.0
DDT0.99963.24.681 ± 199 ± 97.3
CAR0.99875.18.287 ± 10112 ± 787
ALA0.99678.910106 ± 7117 ± 215
DIE0.99235.19.682 ± 4107 ± 115
Plasticizers
DIBP0.99925.87.4102 ± 788 ± 310
DBP0.99906.21091 ± 485 ± 37.5
DMEP0.99912.97.589 ± 688 ± 237
DIPP0.99826.31177 ± 298 ± 110
DPP0.99925.91090 ± 386 ± 26.4
BBP0.99768.81080 ± 5105 ± 1534
DEHP0.99985.17.878 ± 399 ± 115
BPA0.99531.55.6n.c.110 ± 2n.c.
Nitrosamines
NDEA0.99611.63.899 ± 2103 ± 826
NPYR0.99491.52.5119 ± 2118 ± 260
NDPA0.99430.73.5115 ± 1106 ± 812
NMOR0.99792.55.6101 ± 3101 ± 675
NPIP0.99791.56.3112 ± 2115 ± 842
NDBA0.99722.15.2116 ± 2118 ± 890
NDPhA0.99982.315116 ± 3118 ± 212
NMA0.99731.47.6107 ± 12102 ± 1040
NEA0.99282.33.690 ± 4100 ± 3150
NDBzA0.99763.89.2109 ± 10101 ± 486
Other compounds: oxidative dyes and fragrances
Hydroquinone0.99893.65.271 ± 989 ± 10200
2-NAP0.99807.19.0106 ± 7110 ± 1271
ATTN0.99964.36.5117 ± 294 ± 14.1
MA0.99653.64.4101 ± 383 ± 210
MM0.99332.64.3107 ± 677 ± 912
MT0.99644.24.089 ± 1083 ± 28.8
Lyral®0.99374.65.5114 ± 297 ± 120
a LODs were calculated for the leave-on cosmetic sample. n.c. Not calculated since there was matrix interference.
Table 3. µMSPD-LC-MS/MS performance. Coefficient of determination (R2), precision, accuracy, and limits of detection (LOD).
Table 3. µMSPD-LC-MS/MS performance. Coefficient of determination (R2), precision, accuracy, and limits of detection (LOD).
APs and APEOsLinearityPrecisionRecovery, %LOD (ng g−1)
Linear Range,
(µg L−1)
R2Intra-Day, RSD, %Inter-Day, RSD, %Leave-OnRinse-OffLeave-OnRinse-Off
NP + 4 NP2–10,0000.99982.38.490 ± 583 ± 70.110.09
NPEO10–10,0000.99925.69.2106 ± 788 ± 101.120.36
OPEO10–10,0000.99744.45.092 ± 494 ± 111.300.26
NP4010–10,0000.99988.79.191 ± 390 ± 30.220.37
TX-10020–10,0000.99979.910100 ± 296 ± 21.140.65
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Celeiro, M.; Rubio, L.; Garcia-Jares, C.; Lores, M. Multi-Target Strategy to Uncover Unexpected Compounds in Rinse-Off and Leave-On Cosmetics. Molecules 2021, 26, 2504. https://doi.org/10.3390/molecules26092504

AMA Style

Celeiro M, Rubio L, Garcia-Jares C, Lores M. Multi-Target Strategy to Uncover Unexpected Compounds in Rinse-Off and Leave-On Cosmetics. Molecules. 2021; 26(9):2504. https://doi.org/10.3390/molecules26092504

Chicago/Turabian Style

Celeiro, Maria, Laura Rubio, Carmen Garcia-Jares, and Marta Lores. 2021. "Multi-Target Strategy to Uncover Unexpected Compounds in Rinse-Off and Leave-On Cosmetics" Molecules 26, no. 9: 2504. https://doi.org/10.3390/molecules26092504

Article Metrics

Back to TopTop