Next Article in Journal
Modeling of a Biomass Cogeneration Plant from a Gasification Process
Previous Article in Journal
The Dynamic Cointegration Relationship between International Crude Oil, Natural Gas, and Coal Price
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
Article

Analysis of Stray Current Leakage in Subway Traction Power Supply System Based on Field-Circuit Coupling

1
Guangzhou Metro Design & Research Institute Co., Ltd., Guangzhou 510010, China
2
School of Electrical and Automation Engineering, East China Jiaotong University, Nanchang 330013, China
*
Author to whom correspondence should be addressed.
Energies 2024, 17(13), 3121; https://doi.org/10.3390/en17133121
Submission received: 20 May 2024 / Revised: 11 June 2024 / Accepted: 18 June 2024 / Published: 25 June 2024

Abstract

In a rail transit system, there is a constant leakage of current from the subway rails to the earth, and these stray currents have complex propagation paths and a wide range of influence. Since no stray current collection devices are installed at subway depots, some of the stray current leaking from the mainline will converge at the depot, seriously corroding the structural reinforcement and buried metal of the station, thereby jeopardizing the normal operation of subway trains and passenger safety. In this paper, a field-circuit coupling method is proposed to analyze the current leakage and distribution law of the subway mainline and depot. It is found that the failure of the gauge block at the mainline will trigger the maximum leakage of rail current. Additionally, it is observed that the stray current distribution at the depot is mainly influenced by the operating status of the one-way conduction device (OWCD) and the change of rail potential. These results validate the applicability and effectiveness of the field-circuit coupling method proposed in this paper and provide new technical support for the study of stray current leakage distribution in subways.
Keywords: subway; stray current; leakage; distribution; field-circuit subway; stray current; leakage; distribution; field-circuit

Share and Cite

MDPI and ACS Style

Lin, S.; Tang, Z.; Chen, X.; Liu, X.; Liu, Y. Analysis of Stray Current Leakage in Subway Traction Power Supply System Based on Field-Circuit Coupling. Energies 2024, 17, 3121. https://doi.org/10.3390/en17133121

AMA Style

Lin S, Tang Z, Chen X, Liu X, Liu Y. Analysis of Stray Current Leakage in Subway Traction Power Supply System Based on Field-Circuit Coupling. Energies. 2024; 17(13):3121. https://doi.org/10.3390/en17133121

Chicago/Turabian Style

Lin, Shan, Zhixi Tang, **a Chen, Xuehua Liu, and Yunsheng Liu. 2024. "Analysis of Stray Current Leakage in Subway Traction Power Supply System Based on Field-Circuit Coupling" Energies 17, no. 13: 3121. https://doi.org/10.3390/en17133121

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop