Energy, Exergetic, and Thermoeconomic Analyses of Hydrogen-Fueled 1-kW Proton-Exchange Membrane Fuel Cell

by
Yungpil Yoo
1,2,
Sang-Yup Lee
1,3,
Seok-Ho Seo
2,
Si-Doek Oh
2 and
Ho-Young Kwak
2,4,*
1
Department of Climate Change Energy Engineering, Yonsei University, Seoul 03722, Republic of Korea
2
Blue Economy Strategy Institute Co., Ltd., #602, 150 Dogok-ro, Gangnam-gu, Seoul 06260, Republic of Korea
3
Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul 03722, Republic of Korea
4
Department of Mechanical Engineering, Chung-Ang University, Seoul 06974, Republic of Korea
*
Author to whom correspondence should be addressed.
Entropy 2024, 26(7), 566; https://doi.org/10.3390/e26070566
Submission received: 15 May 2024 / Revised: 18 June 2024 / Accepted: 28 June 2024 / Published: 30 June 2024
(This article belongs to the Special Issue Thermal Science and Engineering Applications)

Abstract

Exergy analysis evaluates the efficiency of system components by quantifying the rate of entropy generation. In general, the exergy destruction rate or irreversibility rate was directly obtained through the exergy balance equation. However, this method cannot determine the origin of the component’s entropy generation rate, which is a very important factor in system design and improvement. In this study, a thorough energy, exergy, and thermoeconomic analysis of a proton-exchange membrane fuel cell (PEMFC) was performed, providing the heat transfer rate, entropy generation rate, and cost loss rate of each component. The irreversibility rate of each component was obtained by the Gouy–Stodola theorem. Detailed and extensive exergy and thermoeconomic analyses of the PEMFC system determined that water cooling units experience the greatest heat transfer among the components in the studied PEMFC system, resulting in the greatest irreversibility and, thus, the greatest monetary flow loss.
Keywords: entropy generation rate; Gouy–Stodolar theorem; proton-exchange membrane fuel cell (PEMFC); lost cost flow rate entropy generation rate; Gouy–Stodolar theorem; proton-exchange membrane fuel cell (PEMFC); lost cost flow rate

Share and Cite

MDPI and ACS Style

Yoo, Y.; Lee, S.-Y.; Seo, S.-H.; Oh, S.-D.; Kwak, H.-Y. Energy, Exergetic, and Thermoeconomic Analyses of Hydrogen-Fueled 1-kW Proton-Exchange Membrane Fuel Cell. Entropy 2024, 26, 566. https://doi.org/10.3390/e26070566

AMA Style

Yoo Y, Lee S-Y, Seo S-H, Oh S-D, Kwak H-Y. Energy, Exergetic, and Thermoeconomic Analyses of Hydrogen-Fueled 1-kW Proton-Exchange Membrane Fuel Cell. Entropy. 2024; 26(7):566. https://doi.org/10.3390/e26070566

Chicago/Turabian Style

Yoo, Yungpil, Sang-Yup Lee, Seok-Ho Seo, Si-Doek Oh, and Ho-Young Kwak. 2024. "Energy, Exergetic, and Thermoeconomic Analyses of Hydrogen-Fueled 1-kW Proton-Exchange Membrane Fuel Cell" Entropy 26, no. 7: 566. https://doi.org/10.3390/e26070566

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop